TF1 Total Filter

Warranty:
5
Years

This award-winning TF1 Total Filter combines hydrocyclonic action with powerful Neodymium magnetic assemblies, to remove magnetic and non-magnetic contaminants from system water and contain them safely within the filter. It fits onto vertical and horizontal pipework, can be cleaned in minutes, does not restrict flow in any way.

  • Hydrocyclonic and magnetic in-line filter
  • Unique action, removes magnetic and non-magnetic contaminants
  • Dosing point for Fernox ‘F’ range products
  • Cleaned in minutes without removal or disassembly
  • Will not block or restrict flow
  • All valves and fittings included
Available Versions
CodeFit Type and SizeProduct Data SheetSafety Data Sheet (PDF)
60003
Fit Type: With Valves, Imperial Fitting Size (inches): 1" Sweat
Product Overview

The TF1 Delta Filter is manufactured from a high strength engineering grade brass, suitable for heating and cooling system applications. The brass components are nickel plated to increase durability and resistance, meaning the filter is compatible for use with a range of glycols and additives used in central heating systems.

The TF1 Delta Filter has been designed to ensure there is a minimal pressure head loss, whilst also maintaining a high collection efficiency. The Hydrocyclonic action, magnet assembly and area of low flow have all been engineered to allow the filter to capture a range of system contaminates, whilst ensuring this does not impact the rest of the heating system.

The TF1 Delta Filter utilises a range of high-quality component parts that ensure the filter offers the best possible performance. The magnet is made using a premium grade of neodymium, enabling a high efficiency capture rate, combined with a robust drain valve design, which allows the filter to be cleaned without the need for system shutdown.

Application

The recommended in-use concentration of the product is 0.5% and treats a 528 gallon (2000 litre) system. Fernox Protector F1 2.6G can be introduced into the system via a suitable point such as a dosing pot. To ensure speedy dispersion, partly or completely drain down and introduce Protector F1 2.6G whilst refilling. We recommend that untreated systems are thoroughly cleansed and flushed using Fernox Cleaner F3 2.6G before treating with Fernox Protector F1 2.6G, as existing debris can damage the installation. Concentration should be checked regularly using the Fernox Express Inhibitor Test and topped up, if necessary, for maximum protection.

Performance

Suitable Fluids:
Water
Inhibited Glycol Solutions
Fernox Chemical Range /System Additives
Maximum Percentage of Glycol – 50%

Internal Volume – 0.84 US gallons
Maximum Working Pressure – 16 Bar/232 psi
Maximum Flow Rate – 53 US gallons/min
Automatic Air Vent with Auto Shut-off Valve – 12 Bar/174 psi
Maximum Working Temperature – 248⁰F
Capture Rate – Up to 100% of system contaminates

Pressure Loss Data
The TF1 Delta Filter has been hydrostatically tested
according to the Pressure Equipment Directive 97/23/EC
at 24 bars (348 psi) for a PN16 rating

Operating Principle – Contaminated water enters the filter via the manifold, carrying a variety of system debris and particulate matter held in suspension. This debris, including ferrous impurities such as Magnetite, move through the manifold and into the main body of the filter.
The TF1 Delta Filter utilises Hydrocyclonic filtration. A Hydrocyclone is a static device that applies centrifugal force to a liquid mixture to promote the separation of particles.
The Hydrocyclonic action has been designed to convert incoming liquid velocity into rotary motion. As water enters the filter, it spins around and down the outside of the filter, carrying particles with it. The shape of the filter has been designed to create a dead zone at the bottom where heavier particles are deposited for safe removal.
The Hydrocyclone in the TF1 Delta Filter has been optimised in order to allow for the maximum filtration ability of both magnetic and non-magnetic material.
Once the flow of water has reached the bottom of the filter, water moves back up through the centre of the TF1 Delta Filter, carrying particles over the magnet sheath, promoting further magnetic filtration, and enhancing the collection capabilities of the filter.
Any dirt collected within the filter can then be discharged by removing the magnet from the sheath and opening the drain valve. This procedure is shown in the cleaning guide and does not require system shutdown or the filter to be disassembled.

Physical Specification / Properties

Form: Light brown liquid
Odour: Slightly aromatic
pH (conc): 8.4
pH (soln): 7.8 to 8.5
SG: 1.17 at 20°C/ 68 F°Form: Light brown liquid
Odour: Slightly aromatic
pH (conc): 8.4
pH (soln): 7.8 to 8.5
SG: 1.17 at 20°C/ 68 F°

Package, Handling & Safety

Self-contained kit includes: 115V Submersible pump, 2 x 4ft hoses (3/4″ NPT fitting) & Fernox DS40 Descaler and Cleaner.

CAUTION: Electricity and water hazard

Volumetrics
CodeFit Type and SizeSingle Unit BarcodeSingle Unit Dimensions
(Height x Width x Depth)
Outer Carton Barcode (ITF)Outer Carton Dimensions
(Height x Width x Depth)
60003
Fit Type: With Valves, Imperial Fitting Size (inches): 1" Sweat
5014551600034
7.05 x 13.62 x 4.41 inches
05014551000292
9.45 x 14.49 x 13.94 inches